Paramete | Function | Set range | Default |
E1 | Lower setpoint limit | -45℃~Set temp. | -30℃ |
E2 | Higher setpoint limit | Set temp.-50℃ | 30℃ |
E3 | Temp.hysteresis | 1~10℃ | 4℃ |
E4 | Comp.start delay time | 0~10Min | 2Min |
E5 | Offset on room temp. | -10~10℃ | 0 |
E6 | Offset on evap.temp. | -10~10℃ | 0 |
F0 | Defrost function | 0=Electric heater 1=Hot gas | 0 |
F1 | Max.Defrost duration | 1-60Min | 20Min |
F2 | Defrost interval time | 0~24Hr | 6Hr |
F3 | Defrost termination temp. | 0-50~0℃ | 8℃ |
F4 | Display during defrost |